Spinning Suction pipe


·  ·  End break suction system has a variety of functions.
  • It removes fibres delivered by the drafting arrangement after an end break and thus prevents mulitple
    end breaks on neighbouring spindles.
  • It enables better environmental control, since a large part of the return air-flow of the aircondition
    system is led past the drafting system, especially the region of the spinning triangle.
  • In modern installations, approx. 40 to 50 % of the return air-flow passes back into the duct system of the
    airconditioning plant via the suction tubes of pneumafil suction system.
  • A relatively high vacuum must be generated to ensure suction of waste fibres
    • for cotton - around 800 pascals
    • for synthetic - around 1200 pascals
  • A significant pressure difference arises between the fan and the last spindle. This pressure difference will be greater , the longer the machine and greater the volume of air to be transported. The air flow rate is  normally between 5 and 10 cubic meter/ hour.
  •  
  • Remember that the power needed to generate an air-flow of 10 cubic meter/ hour , is about 4.5 times the power needed for an air-flow of 6 cubic meter/ hour, because of the significantly higher vacuum level developed at the fan.